Heath Zenith SL-5412 Manuale Utente

Navigare online o scaricare Manuale Utente per Sensori di movimento Heath Zenith SL-5412. Heath Zenith SL-5412 User's Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 0
OPERATION
© 2003 DESA Specialty Products™ 595-5767-02
* resets to Auto Mode at dawn.
MANUAL MODE
ON-TIME
10 5 1 TEST
10 5 1 TEST
ON-TIME
TEST
... back on.
AUTO
1 Second OFF
then...
Move ON-TIME Switch to
1, 5 or 10 minutes
Mode Switching Summary
Flip light switch off
for one second then
back on*
MANUAL MODE
AUTO
TEST
Requirements
The Light Control requires 120-volts AC.
If you want to use Manual Mode, the control must be
wired through a switch.
Some codes require installation by a qualified
electrician.
This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.
Model SL-5412
Light Control
Sensor
Cover
Plate
Lamp Holders
2 Wire
Connectors
6 Screws
(3 sizes included)
Gasket
2 Shells
Features
Turns on lighting when motion is detected.
Automatically turns lighting off.
Photocell keeps the lighting off during daylight hours.
LED indicates motion was sensed (day or night).
Motion Sensor Light
Control for Canadian
Tire
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the
calibration time the control will be in the AUTO mode.
Note: When first turned on wait about 1
1
/
2
minutes for
the circuitry to calibrate.
Mounting Bolt
Mounting Strap
Plastic Hanger
Rubber Plug
This package includes:
Mode: On-Time: Works: Day Night
Test 5 Sec x x
Auto 1, 5, 10 min. x
Manual Until Dawn* x
Put the ON-TIME switch on the bottom
of the sensor in the TEST position.
Put the ON-TIME switch in the 1, 5
or 10 minute position.
Manual mode only works at night be-
cause daylight returns the sensor to
AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the ON-
TIME switch in the 1, 5, or 10 position.
Vedere la pagina 0
1 2 3 4 5 6 7 8

Sommario

Pagina 1 - Control for Canadian

OPERATION© 2003 DESA Specialty Products™ 595-5767-02* resets to Auto Mode at dawn.MANUAL MODEON-TIME10 5 1 TEST10 5 1 TESTON-TIMETEST... back on.AUTO1

Pagina 2 - INSTALLATION

2595-5767-02INSTALLATIONFor easy installation, select an existing light with a wallswitch for replacement.WIRE THE LIGHT CONTROL.❒ Turn power off at t

Pagina 3 - SPECIFICATIONS

3595-5767-02MotionMotionTEST AND ADJUSTMENT❒ Turn on the circuit breaker and light switch.Least Sensitive Most SensitiveSensorThe detector is most sen

Pagina 4 - TROUBLESHOOTING GUIDE

4595-5767-02POSSIBLE CAUSE1. A flood lamp is positioned too close tothe sensor or pointed at nearby ob-jects that cause heat to trigger thesensor. (Re

Pagina 5 - Commande d’éclairage à

5595-5767-02Caractéristiques• Allume l’éclairage lorsqu’un mouvement est détecté.• Éteint automatiquement l’éclairage.• Photocellule qui maintient l’é

Pagina 6

6595-5767-02INSTALLATIONPour faciliter l’installation, choisir un appareil d’éclairagedevant être remplacé et qui est déjà commandé par uninterrupteur

Pagina 7 - FICHE TECHNIQUE

7595-5767-02ESSAIS ET RÉGLAGES❒ Mettre en circuit le disjoncteur et l’interrupteurd’éclairage.Le moins sensible Le plus sensibleDétecteurMouvementMouv

Pagina 8 - GUIDE DE DÉPANNAGE

8595-5767-02CAUSE POSSIBLE1. Un projecteur se trouve trop près dudétecteur de la commande d’éclairageou est pointé vers des objets tout prèsdont la ch

Commenti su questo manuale

Nessun commento